DELL EMC D-PE-OE-23 Übungsprüfungen
Zuletzt aktualisiert am 08.05.2025- Prüfungscode: D-PE-OE-23
- Prüfungsname: Dell Technologies PowerEdge Operate 2023
- Zertifizierungsanbieter: DELL EMC
- Zuletzt aktualisiert am: 08.05.2025
A technician suspects that a firmware revision is corrupt. A newer revision is not available and the customer does not want to downgrade to a lower revision.
What should be done when troubleshooting for possible corrupt firmware?
- A . Upload the same firmware revision level
- B . Reset the iDRAC
- C . Use the Lifecycle Controller Parts Replacement feature to bring the components up to the latest firmware revision levels
- D . Disable and re-enable the component then reboot the server
A technician is setting up a previously used server. Upon power up, the PERC alerts them to the presence of a foreign configuration. In the iDRAC storage section, the technician checks Foreign View. The foreign array configuration is the same as the configuration needed for the new project.
What is a recommended way to prepare the disks for the new project?
- A . Edit the foreign configuration and set it to Ready
- B . Import the foreign configuration and perform a full initialization
- C . Format the foreign configuration and clear the controller configuration
- D . Access the Ctrl+R utility, clear the foreign configuration and set up array as needed
How can a technician know whether IDRAC9 System Lockdown mode is enabled?
- A . Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
- B . Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
- C . Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
- D . Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
A server is equipped with 2 CPUs and 12x 8 GB DIMMs, for a total of 96 GB. The OS is not seeing all the memory.
Which memory mode should be configured so that all memory is seen by the OS?
- A . Mirroring
- B . Advanced ECC
- C . Optimizer
- D . Sparing
Which sections are included in the iDRAC Troubleshooting tab?
- A . Post Code, Diagnostics, and Video capture
- B . Diagnostics, Last crash screen, and Post Code
- C . Video capture, Post Code, and Last crash screen
- D . Last crash screen, Video capture, and, Diagnostics
A Dell PowerEdge R740 server with two CPUs has six memory modules that are attached to each CPU. Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.
What should be installed or configured?
- A . No additional memory
Switch to Memory Mirroring - B . Six additional memory modules matching the original
Switch on Single Rank Spare Mode - C . Twelve additional memory modules matching the original (six for each CPU)
Switch to Memory Mirroring - D . No additional memory
Switch on Single Rank Spare Mode
A technician needs to roll back the firmware on a server for the Fiber Channel card. The technician needs to determine the previous version before rolling back the firmware.
How should the technician view the previous and current firmware versions utilizing Lifecycle Controller?
- A . Under Firmware Update, select Launch Firmware Rollback and select Components
- B . Under Hardware Configuration, select Launch Firmware Rollback and select Components
- C . Under Firmware Update, select View Current Versions
- D . Under Hardware Configuration, select View Current Versions
Dell EMC PowerEdge 14G servers support which technology?
- A . iDRAC8
- B . AMD GuardMI
- C . Intel Boot Guard
- D . Quicksync 1.0
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
– 200 TB of Fibre Channel drives on NetApp ONTAP 7
– Environment is expected to grow 200 TB over the next three years
In order to remove the encryption key on the SED drives, which steps are required?
- A . SmartFail the cluster and then remove the drive
- B . Suspend the cluster and then SmartFail the drive
- C . SmartFail and then remove the drive
- D . Suspend the node and then remove the drive
Which iDRAC feature allows users to view video recordings of the last three power cycles?
- A . Diagnostics
- B . Virtual Console
- C . System debug logs
- D . Boot and Crash Capture