A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection.
What is the reason for the failure?
- A . Bluetooth is disabled on the mobile device.
- B . NFC is disabled on the mobile device.
- C . There is no iDRAC IP address configured.
- D . The mobile device is using iOS.
Before deploying a server, a customer needs a technician to configure the front panel LCD to display a custom message that contains the customer’s help desk phone number. However, the server cannot be rebooted.
Where can the technician configure the LCD?
- A . Lifecycle Controller
- B . iDRAC web GUI
- C . System BIOS
- D . iSM
A server has two 1100w power supplies. The system needs to enable or disable power supplies dynamically depending on power needs. Power Supply 2 needs to be main power supply.
Which two settings should the technician change? (Choose two.)
- A . Set Default Power Supply to PSU 2
- B . Enable Hot Spare for power supplies
- C . Set Primary Power Supply to PSU 2
- D . Set Power Cap to 1100w for the system
- E . Enable Power Factor Correction
What is a custom form factor mezzanine card that contains a complete NIC subsystem?
- A . PCIe
- B . LOM
- C . OCP
- D . SNAP I/O
A technician needs to install a PCIe NIC into a production server. Six of the seven PCI slots are already populated.
What does the technician need to verify before installing the PCIe NIC?
- A . Slot priority for the PCIe NIC to be installed
Physical slot specifications - B . Physical slot specifications only
- C . Server is connected to 220V power
Slot priority for the PCIe NIC to be installed - D . CPU configuration
Server is connected to 220V power
What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?
- A . NVDIMMs cannot be mixed with RDlMMs
- B . LRDIMMs can be mixed only with RDlMMs
- C . RDlMMs can be mixed only with NVDIMMs
- D . NVDIMMs can be mixed only with LRDIMMs
From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed.
How did this value change?
- A . 8 to 32
- B . 16 to 64
- C . 16 to 32
- D . 8 to 16
After a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster in the future, even at the expense of stowing users down.
How should the technician perform this task?
- A . Change the System Profile to Performance in the System BIOS Setting
- B . Change the Rebuild Rate in the System BIOS Settings
- C . Change the System Profile 1o performance in the iDRAC GUI
- D . Change the Rebuild Rate from me iDRAC GUI
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?
- A . FPGA
- B . PCIe
- C . OCP
- D . NDC
A technician is replacing a fan on a mission critical PowerEdge R740 server that needs to stay operational. The server has no LCD.
How can the technician determine which fan needs to be replaced?
- A . Run embedded diagnostics to locate the failing fan
- B . Access the Lifecycle Controller, navigate to the System > Cooling section to locate the failing fan number
- C . Remove the chassis cover and observe a fan with an amber LED
- D . Use the iDRAC GUI to locate failing fan number