A technician installs a PCIe card into a server, but the card does not appear in the OS. The server does not have an LCD to display errors, but a light is flashing on the front of the server.
What actions can the technician take to troubleshoot the issue?
- A . Initiate Hardware Stress Test from iDRAC GUI
Check PCIe Bus Log for errors - B . Run Hardware Diagnostics from Lifecycle Controller
Review the Lifecycle Controller log for errors - C . Run Hardware Diagnostics from Lifecycle Controller
Initiate Hardware Stress Test from iDRAC GUI - D . Review the Lifecycle Controller log for errors
Check PCIe Bus Log for errors
A technician needs to use the Lifecycle Controller to update the server usingftp.dell.com.
Which step must the technician take to complete this task?
- A . Download the repository to a local USB
- B . Providethe FTP credentials
- C . Configure the Lifecycle Controller with an IP address
- D . Enable FTP protocol in the Lifecycle Controller
A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency.
Which setting can they enable to achieve this?
- A . Logical Processing
- B . Performance per Watt (DAPC)
- C . Adjacent Cache Line Prefetch
- D . Performance per Watt (OS)
Which tool provides automated Dell support case creation?
- A . SupportAssist Collector
- B . OpenManage Case Creator
- C . OpenManage Server Administrator
- D . SupportAssist for IDRAC / Enterprise systems
The system administrator deployed the Dell PowerEdge server. No iDRAC license was purchased with the server.
Which features are available?
- A . Remote syslog, two-factor authentication, and zero touch provisioning
- B . Profile-based configuration, email alerts, and directory services
- C . Email alerts, advanced power monitoring, and profile-based configuration
- D . Advanced power monitoring, autodiscovery, and virtual folders
In which Dell EMC PowerEdge server generation was the BOSS card introduced?
- A . 12G
- B . 13G
- C . 14G
- D . 15G
A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array. They back up data and look in iDRAC Storage and find that the current RAID 5 array is sliced into two virtual disks.
What should the technician do to achieve the desired RAID level?
- A . Reboot and press Ctrl-R to complete RAID migration
- B . Use iDRAC GUI under Storage Configuration to delete the arrays and recreate the new RAID 6 array
- C . Open the OpenManage Enterprise GUI, delete the arrays, and recreate the new RAID 6 array
- D . Use SupportAssist Enterprise to complete RAID migration
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?
- A . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server stays operational - B . Remaining fans stay at the recommended RPM
iDRAC slows down the speed of the CPUs to avoid a temperature increase
LCD changes to blue but an alert would have been sent out - C . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server performs a controlled shutdown - D . Remaining fans increase RPM to compensate for the removed fans
LCD changes to blue and displays an error description
Server performs a controlled shutdown
A technician resets the iDRAC but when they attempt to log back in to the iDRAC is offline.
Why is the iDRAC offline?
- A . DRAC has reset to the default IP address of 192.168.0.120
- B . Technician must use iDRAC Direct to enable the iDRAC network
- C . iDRAC is still in the reset process
- D . Technician must move the iDRAC network cable back to the iDRAC dedicated NIC
A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician’s PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.
What method could the technician use to determine what IP address is assigned to the iDRAC?
- A . Use the iDRAC Direct feature. Access iDRAC web GUI and determine the assigned IP address
- B . Plug a monitor or KVM into the system. Reboot the server to view the assigned IP iDRAC address on the Dell boot up splash screen
- C . Log in to the Lifecycle and check the iDRAC Settings.
- D . Hold the system identification button down for more than 3 seconds to reset it back to the default static address 192.168.0.120