Taking Huawei OceanStor all-flash devices as an example, which of the following descriptions of logical ports are correct? (Multiple Choice)
- A . Logical ports are created based on bonded ports, VLAN ports, or Ethernet ports
- B . Logical ports are virtual ports that carry host services
- C . Each logical port will be assigned an IP address to carry the corresponding business
- D . Different logical ports can be assigned the same IP address
The SCSI protocol is the basic protocol for communication between the host and the disk. It is operated by the SCSI controller. The controller is equivalent to a small CPU with its own command set and cache.
- A . True
- B . False
According to the changes in the amount of backup data, the types of backups can be divided into ______. (Multiple choice)
- A . Real-time backup
- B . Full backup
- C . Incremental backup
- D . Differential backup
The QoS of the file system supports IO priority configuration and also supports policy configuration.
- A . True
- B . False
Which of the following snapshots are correct? (Multiple Choice)
- A . Snapshot recovery technology can be used to detect the business volume of the last month
- B . Can detect business volume in real time
- C . You can use snapshot recovery data to recover data lost by physical problems
- D . Can use snapshot technology to test and develop software
Which of the following objectives with the minimum value can be controlled by Smart QoS policy? (Multiple Choice)
- A . Bandwidth
- B . Standard IOPS
- C . Delay
- D . Capacity
The allocation of storage space when writing is Capacity-on-write, and the redirection of reading and writing is Direct-on-time.
- A . True
- B . False
Regarding the high reliability and cross-data center disaster recovery methods in the data center under the traditional mode and cloud computing mode, which of the following is wrong?
- A . In the traditional mode, the data center relies on component redundancy to achieve high reliability
- B . In the cloud computing mode, the data center relies on component redundancy to achieve high reliability
- C . Under the traditional model, cross-data center disaster recovery is mainly based on copying business data, and the recovery process is complicated and the recovery period is long.
- D . In the cloud computing model, cross-data center disaster recovery is all the data replication of business data and operating environment. The integrated management and recovery process is simple and the recovery period is short.
The al-flash storage product features high reliability.
Which of the following technologies are used to ensure high reliability of the system?
- A . Dual-redundancy design and active-active working mode
- B . Power-off protection
- C . Coffer disk
- D . Advanced data protection technologies, such as HyperSnap and HyperReplication