Huawei H13-629_V3.0-ENU Übungsprüfungen
Zuletzt aktualisiert am 09.03.2026- Prüfungscode: H13-629_V3.0-ENU
- Prüfungsname: HCIE-Storage (Written) V3.0
- Zertifizierungsanbieter: Huawei
- Zuletzt aktualisiert am: 09.03.2026
A company’s business runs on a set of Huawei all-flash storage devices. During the inspection, the operation and maintenance engineer found that the average latency on the host side was 1000 ms and the average latency on the storage side was 800 ms. The operation and maintenance engineer should collect storage operation information and logs and open the performance monitoring tool to analyze the front-end host port, cache performance, LUN performance, and hard disk performance.
- A . True
- B . False
Which of the following descriptions of Huawei’s data protection-body solution is correct? (Multiple choice)
- A . Designed for the local solution of the SMB (Small to Medium-sized Business) market, it supports LAN-Base and LAN-Free backup methods.
- B . The integrated backup solution can provide 2*10GE and 4+CE network cards to carry backup data, reducing the impact of backup operations on business systems.
- C . When the backup data capacity exceeds the storage capacity of the integrated backup node, multiple integrated backup nodes need to be deployed.
- D . The integrated backup node uses Huawei Taishan 2280V2 server and integrates the industry-leading backup software. It integrates server, backup media, and backup software in one , and is ready for use right after it is turned on, reducing the delivery time and difficulty of service engineers in the customer’s live network.
After remote is configured in Huawei all-flash storage, if the slave storage system loses power or fails, the master service will not be affected, but the remote relationship between the master and slave will be disconnected.
- A . True
- B . False
In Huawei OceanStor Pacific, the management node is used to deploy the () management process, which is responsible for the system’s alarm, monitoring, logging, configuration and other operational maintenance functions.
In Huawei OceanStor storage system, when creating a clone, the original LUN can be a thick LUN or a thin LUN, and the secondary LUN can only be a thin LUN.
- A . True
- B . False
Which of the following understandings of the features of Huawei’s eReplication disaster recovery management software are wrong? (Multiple choice)
- A . Supports logging into the resources in the specified recovery plan to perform manual fault recovery when the production site fails.
- B . Supports visual display of disaster recovery network topology and presents the associated logical relationship between disaster recovery host applications
- C . Support inserting custom scripts to expand disaster recovery capabilities during disaster recovery
- D . Supports cleaning up the drill data of the disaster recovery site without affecting production business
In the backup scenario of Huawei data backup appliances, deduplication types can be divided according to different granularities. Which of the following granularities does online deduplication use?
- A . Block-level deduplication
- B . Storage pool deduplication
- C . File-level deduplication
- D . Byte-level deduplication
The deployment process of the disaster recovery system in Huawei’s active-standby disaster recovery solution.
① Solution networking
② Synchronize data to the disaster recovery end
③ Deploy the disaster recovery management server on the disaster recovery end
④ Configure protection groups and recovery plans
⑤ Acceptance testing
- A . True
- B . False
Which of the following descriptions is correct about the homogeneous online migration solution based on Huawei’s heterogeneous virtualization technology?
- A . The target storage is Huawei OceanStori hybrid flash storage. Currently only Linux 3 hosts are supported.
- B . The host must use Huawei’s self-developed multipath
- C . Select "Third-party camouflage" in heterogeneous virtualization operation
- D . The migration target LUN and edevLUN must have the same controller
When the two-site three-center solution adopts the "active-active + asynchronous" networking to achieve disaster recovery, which of the following key technologies does not include active-active in the same city?
- A . Regional Optimized Access
- B . Cache-based multi-time point technology
- C . Cross-center storage cluster
- D . Uninterrupted access to faults