In Huawei OceanStor Dorado high-end series products, which of the following networking supports the use of shared interface modules?
- A . FC networking
- B . IP SAN Networking
- C . DAS Networking
- D . NAS Networking
Through the cross-data center dual-active + asynchronous two-site three-center solution, the RPO of the same city business can be achieved = 0, RTO = 0, and the RPO of the remote disaster recovery center can be achieved in minutes through the multi-time point technology.
- A . True
- B . False
A bank’s core system has database services and file system services. It can purchase a set of Huawei hybrid flash storage devices that support SAN and NAS dual-active and implement load-balanced dual-active mirroring.
- A . True
- B . False
Huawei’s hybrid flash storage devices are highly scalable and support () technology to achieve performance improvement as the number of controllers increases.
Which of the following are the main performance indicators of the front-end port? (Multiple choice)
- A . IOPS
- B . Average read I/O response time
- C . Bandwidth
- D . Average write I /O response time
- E . CPU utilization
When Engineer A was implementing storage delivery, he was unable to scan the LUN on the Linux service host. Which of the following descriptions is wrong?
- A . Storage pool failure
- B . Link failure
- C . Zone configuration error
- D . The host does not have multipath software installed
In which of the following aspects is the business isolation of multi-tenants mainly reflected? (Multiple choice)
- A . Business monitoring isolation
- B . Business data isolation
- C . Business configuration isolation
- D . Business access isolation
A company purchased a Huawei hybrid flash system as a decision support system and planned to perform performance adjustments.
After the test, the storage engineer can obtain the following information:
1) The size of each /0 ranges from 64KB to 1MB
2) The percentage of sequential read I/Os is 90%.
3) The average front-end bandwidth utilization rate is 90%.
4) The host application is a database.
Based on the above information, which of the following performance tuning actions would not be appropriate in this situation?
- A . Use the OLAP model as a reference model for adjustment
- B . Use the OLTP model as a reference model for adjustment
- C . Use smart caching.
- D . Increase the front-end service bandwidth.
The networking switches in Huawei OceanStor Pacific series storage can be either Ethernet switches that support RoCE protocol or IB switches.
- A . True
- B . False
An enterprise uses Huawei hybrid flash memory devices as file storage, with a total storage capacity of 300TB. The enterprise has three business departments: Online transaction business department A, instant messaging service department B, and archiving business department C.
Which of the following options are correct for file system planning? (Multiple choice)
- A . When you need to limit the space or number of files used by a single user, you can choose to create a user quota
- B . You can select the corresponding application type and deduplication and compression activation status based on the IO model of the three departments‘ business.
- C . Due to file system occupancy, redundancy strategy, etc., the directory quota size of the first-level directory cannot exceed 300 TB.
- D . When you need to limit the space or number of files used by a single department, you can create a user group quota