In the HPC scenario, which of the following features does the DPC of the OceanStor Pacific series file service not support?
- A . SmartTier
- B . HyperSnap
- C . SmartQoS
- D . SmartQuota
An enterprise plans to deploy Huawei eReplication disaster recovery management software to protect its business. After the enterprise engineer installed the Agent on the business host and connected it to eReplication, he uninstalled the host Agent due to an error. After reinstalling the Agent, the corresponding host status on eReplication is displayed as "offline". Which of the following is a possible cause of this failure?
- A . The HostSN of the host conflicts with the HostSN of eReplication.
- B . Insufficient space in the "/home/rdadmin/Agent" directory
- C . The host’s Agent port is occupied by other processes
- D . When uninstalling the host Agent, the "/home/rdadmin/Agent" directory was directly deleted.
A company purchased a set of Huawei hybrid flash devices and ran services on a virtualized platform. The host system used Huawei multipath software and was connected to the two controllers of the storage system using an Ethernet switch. Storage engineers found service interruptions and delays on the host. After inspection, they found that the active link of the multipath software was continuously switched. Under the premise of ensuring service reliability, disassembling the multipath software can solve this problem.
- A . True
- B . False
The enterprise storage engineering is designing an enterprise data backup solution, which requires full backup every Sunday, incremental backup every day from Monday to Saturday, and a 4-week data storage period for full backup and incremental backup. Assuming the initial data volume is 400 GB and the daily increment is 20 GB, then 5480 GB is the back-end storage data volume after four weeks.
- A . True
- B . False
An enterprise has deployed Huawei eBackup to back up and protect business data. Currently, the enterprise engineer has completed the initial configuration of the eBackup backup agent and backup server. Please assist the engineer in sorting out the subsequent configuration logic and linking the configuration operations with their corresponding sequence.
Snapshot copy is a technology that backs up the snapshot at the moment of activation. It contains the private data of the snapshot after activation.
- A . True
- B . False
In Huawei’s OceanStor Dorado all-flash storage system, SmartQos flow control management is implemented through three parts: I/O classification queue management, token distribution, and dequeue control of the controlled object.
- A . True
- B . False
Archiving will expand the capacity of the storage system in the data center. When planning capacity, engineers only need to consider data capacity, file system, RAID level, hot spare space, vault disk and value-added features.
- A . True
- B . False
An enterprise purchased a Huawei hybrid flash storage system and planned to configure NAS services to facilitate file storage and sharing among departments. Which of the following options is wrong in planning and design? (Multiple choice)
- A . The financial department has high data security requirements and can restrict account access rights for non-financial department personnel
- B . Conventional application software can be set to be accessible to each account
- C . NAS is based on file system sharing and has nothing to do with storage pools. You do not need to consider the configuration of storage pools.
- D . The access clients of each department must share the service IP of the NAS of the storage device in the same network segment
A hospital considers improving the reliability of business data and configures volume mirroring for business LUO in Huawei hybrid flash memory. During routine inspection, the hospital engineer T found that the "health status" of the mirror LUN on the DiM interface was "faulty". Which of the following is not a possible cause of the fault?
- A . Single-disk enemy barrier
- B . Storage pool failure
- C . The mirror LUN itself fails
- D . Any mirror copy of the mirrored LUN fails